WALTHER Charging station EVOLTUTION 350
new product generation with designer aluminum housing
for semi-public and public area.
stand-alone or master charging station including system integration PRO
according to the charging of electric vehicles IEC 61851,
wired ready for connection,
with the following important features and functions:
Charging point 1
Charging socket type 2 up to 32A / 22kW,
with electromechanical interlock for charging according mode 3,
Emergency release in case of power failure
All common charging cable cross sections from 3.7kW to 22kW are usable
(current comparison according. IEC 61851-1 Ed. 3) Residual current device (RCD) type B, 4-pole 40/0,03A, AC/DC sensitive
Miniature circuit breaker (MCB) 3-pole 32A C and 3-pole 16A C
Charging point 2
Charging socket type 2 up to 32A / 22kW,
with electromechanical interlock for charging according mode 3,
Emergency release in case of power failure
All common charging cable cross sections from 3.7kW to 22kW are usable
(current comparison according. IEC 61851-1 Ed. 3) Residual current device (RCD) type B, 4-pole 40/0,03A, AC/DC sensitive
Miniature circuit breaker (MCB) 3-pole 32A C and 3-pole 16A C
The listed charging points can be used at the same time
The evaluation of the charging power results from an integrated
electric energy meter with RS485/Modbus interface.
These energy meters have direct measurement and are MID certified
Warning when incorrect phase sequence
Signaling of operating statuses via LED-signal lamp
Systems integration PRO in the Stand-alone operation
User interface and load dialog via touch screen with color display
Operation with the following authorization and accounting systems possible:
LPIn: Identification and activation of the charging points by entering
a PIN(internal local list)
LTAN: Identification and one-time activation of the charging points by entering
a TAN (internal local list)
LRFID: Identification and activation of the charging points by RFID medium
(internal local list)
ERFID: identification and disconnection of the charging points by RFID medium,
Communication to the Backend via modem with GSM antenna, OCPP 1.5
(Link with supranational customer roles of e-roaming),
A separate contract must be concluded with the system provider
The required SIM card, configuration data and RFID cards must be provided
5 suitable RFID cards are included in the delivery
Additional equipment:
household socket with RCD / MCB combination (RCBO) 2-pol. 6A B
Network transfer terminal for Ethernet (earth cable on patch cable)
PE M-Bus transfer terminal
5-Port-Switch
25l bag base filler LIAPOR as accessory pack
Housing made of aluminium, powder-coated
corpus pure white (RAL 9010), door, flashback and
panel jet black (RAL 9005)
Dimensions HxWxD approx. 1500 x 380 x 300mm
Weight approx. 75kg
Degree of protection IP 44
Connecting power max. 44kVA
Input fuse max. 63A
Connecting terminal up to 2x5x25sqmm
Installation on foundation, solid surface or
optionally available in stainless steel Finish foundation